Review



single-lead bipolar ecg device alivecor veterinary heart monitor  (AliveCor Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    AliveCor Inc single-lead bipolar ecg device alivecor veterinary heart monitor
    Single Lead Bipolar Ecg Device Alivecor Veterinary Heart Monitor, supplied by AliveCor Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/single-lead+bipolar+ecg+alivecor+veterinary+heart+monitor/single+lead+bipolar+ecg+device+alivecor+veterinary+heart+monitor/pm30559174-42-6-10
    Average 90 stars, based on 1 article reviews
    single-lead bipolar ecg device alivecor veterinary heart monitor - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Software:

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows
    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Article Title: Evaluation of a Smartphone Electrocardiograph in Healthy Horses: Comparison With Standard Base-apex Electrocardiography
    Article Snippet: 91 A smartphone ECG tracing was simultaneously recorded, starting and ending at the 92 same time as the standard ECG, using a single-lead bipolar ECG (AliveCor 93 Veterinary Heart Monitor, AliveCor, USA) and its software interface (AliveECG Vet, 94 M AN US CR IP T AC CE PT ED ACCEPTED MANUSCRIPT 5 AliveCor, USA), as previously described [22].

    Produced:

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows
    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Article Title: Evaluation of a Smartphone Electrocardiograph in Healthy Horses: Comparison With Standard Base-apex Electrocardiography
    Article Snippet: 91 A smartphone ECG tracing was simultaneously recorded, starting and ending at the 92 same time as the standard ECG, using a single-lead bipolar ECG (AliveCor 93 Veterinary Heart Monitor, AliveCor, USA) and its software interface (AliveECG Vet, 94 M AN US CR IP T AC CE PT ED ACCEPTED MANUSCRIPT 5 AliveCor, USA), as previously described [22].



    Similar Products

    90
    AliveCor Inc single-lead bipolar ecg device alivecor veterinary heart monitor
    Single Lead Bipolar Ecg Device Alivecor Veterinary Heart Monitor, supplied by AliveCor Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/single-lead+bipolar+ecg+alivecor+veterinary+heart+monitor/single+lead+bipolar+ecg+device+alivecor+veterinary+heart+monitor/pm30559174-42-6-10
    Average 90 stars, based on 1 article reviews
    single-lead bipolar ecg device alivecor veterinary heart monitor - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    AliveCor Inc single-lead bipolar ecg alivecor veterinary heart monitor
    Dorsoventral orientation with a 30° cranial inclination of the smartphone, with the case maintained in touch with the skin and the smartphone screen pointed toward the investigator for a real‐time visualization of the <t>ECG</t> trace. The smartphone was held with the camera located ventrally while the “start button” was located dorsally
    Single Lead Bipolar Ecg Alivecor Veterinary Heart Monitor, supplied by AliveCor Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/single-lead+bipolar+ecg+alivecor+veterinary+heart+monitor/single+lead+bipolar+ecg+alivecor+veterinary+heart+monitor/pmc06430901-39-20-23
    Average 90 stars, based on 1 article reviews
    single-lead bipolar ecg alivecor veterinary heart monitor - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Dorsoventral orientation with a 30° cranial inclination of the smartphone, with the case maintained in touch with the skin and the smartphone screen pointed toward the investigator for a real‐time visualization of the ECG trace. The smartphone was held with the camera located ventrally while the “start button” was located dorsally

    Journal: Journal of Veterinary Internal Medicine

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows

    doi: 10.1111/jvim.15396

    Figure Lengend Snippet: Dorsoventral orientation with a 30° cranial inclination of the smartphone, with the case maintained in touch with the skin and the smartphone screen pointed toward the investigator for a real‐time visualization of the ECG trace. The smartphone was held with the camera located ventrally while the “start button” was located dorsally

    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Techniques:

    Standard ECG (A) and smartphone ECG (B) tracings in a cow. Paper speed = 50 mm/s (A and B); gain = 10 mm/mV (A) and 20 mm/mV (B)

    Journal: Journal of Veterinary Internal Medicine

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows

    doi: 10.1111/jvim.15396

    Figure Lengend Snippet: Standard ECG (A) and smartphone ECG (B) tracings in a cow. Paper speed = 50 mm/s (A and B); gain = 10 mm/mV (A) and 20 mm/mV (B)

    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Techniques:

    Median and range (minimum and maximum) of the values obtained with the standard  ECG  and smartphone  ECG  methods

    Journal: Journal of Veterinary Internal Medicine

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows

    doi: 10.1111/jvim.15396

    Figure Lengend Snippet: Median and range (minimum and maximum) of the values obtained with the standard ECG and smartphone ECG methods

    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Techniques:

    Limits of agreement (Bland‐Altman) plots showing differences between heart rate (HR) values manually measured on standard ECG (HRst) and (A) smartphone ECG tracings (HRsm) and (B) values produced by the smartphone application (HRapp); (C) differences between duration of P wave measured on standard ECG (ECGst) and smartphone ECG tracings (ECGsm); (D) differences between PR interval measured on ECGst and ECGsm; (E) differences between QRS complex measured on ECGst and ECGsm; and (F) differences between QT interval measured on ECGst and ECGsm

    Journal: Journal of Veterinary Internal Medicine

    Article Title: Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows

    doi: 10.1111/jvim.15396

    Figure Lengend Snippet: Limits of agreement (Bland‐Altman) plots showing differences between heart rate (HR) values manually measured on standard ECG (HRst) and (A) smartphone ECG tracings (HRsm) and (B) values produced by the smartphone application (HRapp); (C) differences between duration of P wave measured on standard ECG (ECGst) and smartphone ECG tracings (ECGsm); (D) differences between PR interval measured on ECGst and ECGsm; (E) differences between QRS complex measured on ECGst and ECGsm; and (F) differences between QT interval measured on ECGst and ECGsm

    Article Snippet: A smartphone ECG tracing was recorded simultaneously, starting and ending at the same time as the standard ECG, using a single‐lead bipolar ECG (AliveCor Veterinary Heart Monitor; AliveCor, San Francisco, California) and its software interface (AliveECG Vet; AliveCor).

    Techniques: Produced